DC-ITSafe
The modular compact data center for the protection of your IT infrastructure.
- high available IT protection
- compact on less than 2 m²
- flexible and modular expandable
- maximum IT security
- standard with double-leaf doors
- monitoring and energy efficient systems
- fully redundant cooling system possible
- cooling units designed for continuous operation
- ready for immediate use - available ex stock
The modular Mini Data Center
DC-ITSafe grows with the requirements
- Extendable with patented "Click" assembly method for the quick and easy assembly / disassembly.
- Extendable, reduceable or relocatable within short notice.
Our DC-ITSafe is available in different versions. These versions differ on variable positioned recesses for all important connections. This enables us to react purposeful on your individual requirements. Cable ducts can be placed in side panels as well as in floor and ceiling panels. Furthermore, if required it is possible to string any number of Mini Data Center together and to link with each other. DC-ITSafe grows simple with increased need and guarantees greatest possible flexibility.
From industrial customers across the medical field through to the office environment
DC-ITSafe withstands the circumstances and variety of various locations and is qualified across all businesses like for example in small and mid-sized companies, companies with decentralized structures (Logistics and industrial companies with various locations, chains), medical facilities like large group practices or hospitals, financial auditors, legal firms, engineering offices, architects or marketing agencies.
Benefit from space-saving all round protection for your IT infrastructure. You can determine the location for Mini Data Centers regardless of the spatial conditions in your company. Dusty production facilities with a high noise level or a heating room with high humidity? No problem for our DC-ITSafe! Our Edge Micro Center adapts to your requirements and protects your data also under difficult circumstances.
Technical Details
Technical features | DC-ITSafe HU 56 |
---|---|
OUTER DIMENSIONS | |
Width (mm) | 1,452 |
Height (mm) | 2,185 |
Depth (mm) | 1,470 |
Profile Frame (inch, mm) | 19": 800 x 1,200 |
HEIGHT UNITS | |
Horizontal | 44 |
Vertical | 12 |
Total | 56 |
WEIGHT | |
Weight empty (kg) | ca. 1,100 |
Maximum capacity 19” (kg) | 1,000 |
SETTING | |
Patented "click" assembly method | ● |
Self-locking, multiple automatic locking by massive swing fasteners and tightness elements | ● |
Number of soft ducts (optional hard ducts or firestop sleeve) | 4 |
Possible positioning cable dutcs | in the side, floor or ceiling elements |
Locking possibilities | Codecard lock, key lock and/or pin-code-terminal |
Technical features | DC-ITSafe HU 62 |
---|---|
OUTER DIMENSIONS | |
Width (mm) | 1,452 |
Height (mm) | 2,425 |
Depth (mm) | 1,470 |
Profile Frame (inch, mm) | 800 x 1,200 |
HEIGHT UNITS | |
Horizontal | 50 |
Vertical | 12 |
Total | 62 |
WEIGHT | |
Weight empty (kg) | ca. 1,100 |
Maximum capacity 19” (kg) | 1,000 |
SETTING | |
Patented "click" assembly method | ● |
Self-locking, multiple automatic locking by massive swing fasteners and tightness elements | ● |
Number of soft ducts (optional hard ducts or firestop sleeve) | 4 |
Possible positioning cable dutcs | in the side, floor or ceiling elements |
Locking possibilities | Codecard lock, key lock and/or pin-code-terminal |
Functions and options
Double-sided cooling device
Compact split-art indoor and outdoor unit
Rack with bilateral air conditioning
Capacities:
- 1,6 kW - 4,5 kW
- 2,7 kW - 6,7 kW
- 3,3 kW - 8,1 kW
- Compact split units with indoor unit within DC-ITSafe and outdoor unit for the
installation
outside.
- 100% redundancy by two indoor- and outdoor units, rack width 800 mm
- DX-Inverter technology. Refrigerant R410A.
- Improved separation for directed air flow - cold and warm side.
- Different options (e.g. DX-/CW side cooler), capacities up to 8.1 kW upon request.
Functions and options
The DC-MonIToring system allows a direct online access to check the actual status of physical infrastructure components. Also available as MonIToring Alarm as option.
Fire protection!
The mini data center DC-ITSafe was system-tested in accordance with EN 1363-1, fire resistance class EI90 and moreover the limit values of EN 1047-2 for 40 minutes. The video shows the DC-ITSafe during the test in the furnace.
Professional early fire warning and extinguishing system
Appropriate precautions for your data safety (as option). Early fire warning and extinguishing system for just 2 HU.
3-stage security concept:
3-stage security concept:
1. Early, highly sensitive smoke
detection
2. Automatic system shut-down
3. Extinguishing
- Extinguishing agent 1230
- Units incl. power supply and battery buffer
- Master unit for extinguishing volume up of to max. 4,4 m³
Modular expandable by slave units (max. 4 units per master), ea. with an extinguishing volume of 4,4 m³. Vertical installation in lateral duct blinds is possible, this means no loss of HU in the rack.